Advanced Machinery for Electronics Manufacturers | SEIKA Machinery, Inc.

McDry Ultra-Low Humidity Storage Cabinets

Humidity Control by McDry

Hygrometer
ERC-301B
ERC-301B Recommended for ISO-9000

The digital hygrometer ERC-301B is used to monitor humidity levels within McDRY.

Specifications

  • Static capacitance type sensor
  • Measuring range: 1-50% RH
  • Accuracy: ±3% RH
  • 4 AA Alkali batteries; approx. 1-year service life
Features:

Batteries are utilized so that in the event of power supply interruption or when the cabinet is unplugged for relocation, the meter may continue to display the humidity level within the cabinet. Contact us when a calibration certificate is necessary.

IC packages should be stored in a dry box (McDRY) at < 5% RH in conformance with the IPC-JEDEC specification for prevention of moisture absorption and indefinite safe storage of MSDs. However, correct humidity control is impossible unless the hygrometer reading is reliable.Be sure to calibrate the hygrometer at least once a year.

Hygrometer with Alarm
ERC-301AD

By setting the RH limit with the ERC-301AD hygrometer, an alarm light will flash when the humidity level becomes too high.

  1. The alarm light will flash when the humidity level goes over the set limit after a fixed period of time.
  2. After the alarm light flashes, the unit will save 10 data readings, one per hour
  3. When the humidity level goes over the set limit, the (optional) light tower will flash and a buzzer will sound.
ERC-301AD

Specifications

  1. Humidity settings: 5 RH 10 RH 20 RH
  2. Time settings: 60 min. 120 min. 180 min.
  3. Excess humidity: Alarm light flashes
  4. Humidity data after the alarm 10 data
    readings (1 per hour)
  5. Power: 4 AA Alkali batteries; approx.
    1-year service life

Example: Humidity data after the alarm light flashes (1 reading per hour)

Time (h) Humidity RH
0 30
1 30
2 30
3 40
4 40
5 40
6 40
7 40
8 40
9 40

Previous