Advanced Machinery for Electronics Manufacturers | SEIKA Machinery, Inc.

McDry Ultra-Low Humidity Storage Cabinets

IC Package Storage Specified by IPC/JEDEC

Dry Box Storage Guideline as Recommended by IPC/JEDEC J-STD 033B.1
(Handling, Packing, Shipping and Use of Moisture/Reflow Sensitive Mount Devices.)

According to IPC/JEDEC J-STD 033B.1, IC packages should be stored in a dry box capable of maintaining either 10%RH or 5%RH in order to prevent components from absorbing moisture.

Storage in a cabinet below 5%RH: No limit in floor life.
Storage in a cabinet below 10%RH: Please see chart below for examples.

(Section of Table 7-1 from IPC/JEDEC J-STD 033B.1)

Package
Type and
Body
Thickness
Moisture
Sensitivity
Level
Floor life depending on humidity and temperature Temp
5* 10* 20* 30* 40* 50* 60* 70* 80* 90*
Body
Thickness
> 3.1mm
including
PQFPs
>84 pins,
PLCCs
(square)
All
MQFPs
or
All BGAs
> 1mm
2a





94
124
167
231
44
60
78
103
32
41
53
69
26
33
42
57
16
28
36
47
7
10
14
19
5
7
10
13
4
6
8
10
←35ºC
←30ºC
←25ºC
←20ºC
3





8
10
13
17
7
9
11
14
6
8
10
13
6
7
9
12
6
7
9
12
4
5
7
10
3
4
6
8
3
4
5
7
←35ºC
←30ºC
←25ºC
←20ºC
4


3
5
6
8
3
4
5
7
3
4
5
7
2
4
5
7
2
3
5
7
2
3
4
6
2
3
3
5
1
2
3
4
1
2
3
4
←35ºC
←30ºC
←25ºC
←20ºC
5


2
4
5
7
2
3
5
7
2
3
4
6
2
2
4
5
1
2
3
5
1
2
3
4
1
2
2
3
1
1
2
3
1
1
2
3
←35ºC
←30ºC
←25ºC
←20ºC
5a


1
2
3
5
1
1
2
4
1
1
2
3
1
1
2
3
1
1
2
3
1
1
2
2
1
1
1
2
1
1
1
2
1
1
1
2
←35ºC
←30ºC
←25ºC
←20ºC
* %RH
Resetting of Floor Life for MSLs 2~3 in a Dry Box Following IPC/JEDEC J-STD-033B.1(Example of Room Temperature Dehumidification.)

According to IPC/JEDEC J-STD-033B.1, IC packages for moisture-sensitivity levels 2-3 that have been removed from MBBs must be kept in dry storage capable of maintaining no greater than 10% RH. The floor life of these components can be reset if stored in a dry box at 10%RH for five times the exposure period(under the conditions of 30 degrees C, 60% RH.) The exposure time is limited to a maximum of 12 hours.

IC Package Dehumidification
Resetting of Floor Life for MSLs 4~5, 5a in a Dry Box.

IC packages with moisture-sensitivity levels of 4~5,5a should be stored in a dry box capable of maintaining no greater than 5%RH. The floor life of the components can be reset by storing the packages within a dry cabinet capable of maintaining 5%RH or lower for a period of ten times the exposure period (under conditions of 30 degree C, 60% RH). The exposure time is limited to a maximum of 8 hours.

Previous Next